Yes
Yes. You can use filaments from other brands (limited to 1.75mm diameter filaments), but certain parameter adjustments are required due to slight temperature differences in different filaments.
Yes. This function can be enabled in the [Settings] interface.
ABS can release toxic gases during heating. It is recommended to use the HEPA air filter during or after printing. If conditions permit, consider printing in a well-ventilated area. It is recommended to print non-toxic materials such as PLA in children's activity places.
Method 1: Increasing the platform temperature can improve the adhesion between the platform and the model.
Method 2: Adding a raft during model slicing can alleviate the issue.
Method 3: Apply glue.
Method 4: If the distance between the nozzle and platform is too large, reduce it accordingly using the extruder calibration in the expert mode or the leveling and calibration function.
Method 5: Check if the platform is level. The leveling and calibration function can be used. It is recommended to complete the full auto-leveling process.
Not necessarily. Adding a raft results in more filament extrusion and higher print success rate. With a heated build plate, it enhances the adhesion between the model and the platform, which makes the model adhere to the platform well during printing, and also increases the print success rate.
The USB flash drive format is incorrect. The printer supports the FAT32 file system. Please format the USB flash drive to FAT32.
1. Please check if the Wi-Fi name contains special characters. If so, modify it and try again.
2. Please check if the password contains special characters. If so, modify it and try again.
Do not power off the printer or disconnect from the network during firmware download or update to prevent update failures.
If the startup sound can be heard, please replace the screen or cable. If not, please contact our after-sales personnel.
The battery needs to be purchased by yourself.
Model: LR44, 1.5V
Size: 11.6*5.1mm
Compatible model: AG13/A76/L1154
1. Observe the filament guide tube to check if filament has entered the nozzle. If not, please click [Load] until filament comes out.
2. Check if the nozzle is clogged. If so, please refer to this video.
Please do Equipment Calibration for the solution.
There are two ways to find the serial number:
Method 1: Check the label
When our customer support team request the serial number, you can take a photo of the label on the back of your printer and send it to them. The serial number is located in the blue box below.
Method 2: Check on the info interface
2. The serial number is displayed on the info interface, as shown in the blue box below.
In case of systemic issues, identifying the root cause solely based on observable symptoms may prove challenging. Therefore, device logs may be required for further analysis. Follow these steps to copy the logs:
Step 1: On the main interface, click [] to enter the info interface.
Step 2: Then, you'll find [Copy Logs] on the info interface.
Step 3: Insert a USB flash drive into the printer.
Step 4: Click [Copy Logs], and it will start copying the logs to the USB flash drive, as shown below. (*Do not remove the USB flash drive during this process, or the copy will fail.)
Step 5: Once the copying is completed, a notification will pop up. You can then safely remove the USB flash drive from the printer.
Step 6: Export the logs from the USB flash drive and send them to our customer support team for further assistance.